Infrared

MLX90614

Single and dual zone thermometer in TO-39

Object temperature

— Ambient —
Connect the Melexis IO board with an MLX90614 on SMBus.
Object Ambient —

Device

Status
Disconnected
Zones
—
Object 2
—
Emissivity
—
Sample
—
7-bit, 0x08 to 0x77. Detect passes the address it found; the last one used here is remembered. Applies on the next connect.

Emissivity

Applied inside the sensor, not here: it lives in EEPROM cell 0x04 and the readings already account for it. Changing it also rescales a calibration cell and, on newer parts, needs an unlocking key — so this page reads it and leaves it alone.

Latest readings

TimeObjectAmbient
No samples yet.

SCPI log


          

The part linearises and compensates on chip, so there is nothing to port: the temperatures come straight out of RAM at 0.02 °C per count. It speaks SMBus rather than plain I2C — every transaction carries a PEC checksum, which this page verifies, and the bus has to run at 100 kHz or slower. Dual-zone variants report a second object temperature; a single-zone part answers that cell with its error flag set, which is how the page tells them apart.